- About us
-
Products
-
Distribution
-
Firefighting & Fire protection
- Fire Alarm
-
Firefighting
- Fire extinguisher
- Fire hydrant
- Fire pumps
- Fire hose
- Couplings
- Nozzle
- Sprinkler
- Firefighting Foam
- Fire blanket
- Foam inductor
- Confined Breathing Apparatus
- Others...
- Ventilators
- Fire Ladder
- Control Valves
- Automatic filling, testing fire extinguisher
- Fire hose, washing & binding machines
- Fire extinguisher for cars
- Industrial, military & oil-gas lighting
- Fire powder
- Fire - Explosion Proof System
- Oil & Gas
- Life-saving Equipment
- Electrical Safety
-
Labor protection
- Army boots
- Protective Clothing
- Safety gloves
- Safety shoes
- Protective Hats
- Oil/Acid-Resistant Gloves
- Oil/Acid-Resistant Boots
- Heat resistant clothing
- Heat resistant gloves
- Heat resistant boots
- Earmuffs
- Protective Glasses
- Safety belt
- Fall arrester
- Climbing Rope
- Rescue Rope
- Welding Mask
- Toxic Mask
- Others...
- Electrical Construction
- Measuring Instruments
- Security
- Primary equipment
- Lightning Protection
- Mechanical & Electrical
-
Firefighting & Fire protection
- Manufacture
-
Distribution
- Service
-
Project
- Offshore Projects
-
Onshore projects
- Mechanical and Electrical
- Firefighting and Fire protection
- Lightning Systems
- HVAC
- Security, Computer Network
- Helicopter Underwater Escape Training (HUET) Models
- Intelligent warehouse
- Powder coasting system
- Extinguisher powder loading system
- Maintenance, Repair of fire protection, HVAC, Lightning systems
- Thematic - News
- Sitemap
- Contact Us
- Catalogue
Product Category
- Distribution
- Firefighting & Fire protection
- Fire Alarm
- Addressable Fire Alarm Control Panel
- Conventional Fire Alarm Control Panel
- Manual Call Point
- Addressable and Coventional Detectors
- Bell, Strobe and Horn
- Modules
- Others...
- Firefighting
- Fire extinguisher
- Fire hydrant
- Fire pumps
- Fire hose
- Couplings
- Nozzle
- Sprinkler
- Firefighting Foam
- Fire blanket
- Foam inductor
- Confined Breathing Apparatus
- Others...
- Ventilators
- Fire Ladder
- Control Valves
- Automatic filling, testing fire extinguisher
- Fire hose, washing & binding machines
- Fire extinguisher for cars
- Industrial, military & oil-gas lighting
- Fire powder
- Fire - Explosion Proof System
- Oil & Gas
- FM200 Systems
- Wellhead Control Panel
- Metering Systems
- Crane muzzle people
- HVAC system
- Life-saving Equipment
- Electrical Safety
- Insulating Gloves
- Insulating boots
- Insulating Blankets
- Insulating helmet
- Conductive working suit
- Hot stick
- Short - gun sticks
- Earthing equipment
- Others...
- Labor protection
- Army boots
- Protective Clothing
- Safety gloves
- Safety shoes
- Protective Hats
- Oil/Acid-Resistant Gloves
- Oil/Acid-Resistant Boots
- Heat resistant clothing
- Heat resistant gloves
- Heat resistant boots
- Earmuffs
- Protective Glasses
- Safety belt
- Fall arrester
- Climbing Rope
- Rescue Rope
- Welding Mask
- Toxic Mask
- Others...
- Electrical Construction
- Products and Suppliers
- Winch
- Tensioner and Puller
- Wire Grip
- Hydraulic Tools
- Hydraulic Compression Tools
- Hydraulic Cutters
- Hydraulic Punches
- Hydraulic Pumps
- Others...
- Hoists
- Space Car
- Wire-Mesh Grips
- Other...
- Measuring Instruments
- Electrical Measurement
- Clamp Meters
- Multimeters
- Insulation Testers
- Earth Testers
- Micro-resistance Testers
- Power Quality Analyzers
- Electric Detectors
- Others...
- Non-electric Measuring
- Thermometers
- Distant meters
- Portable gas detector
- Plating Thickness Meter
- Security
- Puplic Annoucement System
- Central Controller
- Ministry preamps
- Ceiling Speakers
- Speaker wall box
- Volume control buttons
- Tables call
- Desk call extension
- Camera Systems
- DVR center
- CCTV Day Night
- CCTV IR
- CCTV PTZ
- Bullet cameras
- Primary equipment
- Disconnectors
- Circuit Breaker
- Current Transformer
- Voltage Transformer
- Surge Arrester
- Filter reactor
- Lightning Protection
- Air Terminals
- Lightning Arrester
- Mechanical & Electrical
- Manufacture
- Safety belt
- Earthing Equipment
- Puly
- Safety signs
- Labor Protection
- Protective Clothing
- Safety Gloves
- Puller
- Others...
Manufacturer
- HONEYWELL
- MEDC
- FIKE
- KEY
- SPERIAN
- DRAEGER
- PAN TAIWAN
- PROTECTA
- SAF-T-GARD
- FOMTEC
- KIDDE
- OCV
- MULTRON
- EXCALOR
- NORTH
- BULLARD
- BILLY PUGH
- SEW
- SONEL
- FLIR
- NEWAGE
- PROTEK
- SICK
- YOTSUGI
- GENSET
- PAT NGK
- NINGBO
- FUJII DENKO
- SMC
- QMATIC
- KING'S
- VIET NAM
- FAMECA
- 3M
- BH
- SALISBURY
- MIRCOM
- SECUTRON
- HASTING
- SIEMENS
- ALSTOM
- ABB
- TRENCH
- TYCO
- TOSHIBA
- NGK
- OBO
- KYORITSU
- HIOKI
- HAGLOF
- LEICA
- INGESCO
- PULSAR
- PRODUCTOS MESA
- KAC
- SHIN YI
- KLEIN TOOLS
- CHINA
- LHRMarine
- DANIAMANT
- HWASEUNG EXWILL
- PROTECTOR
- IZUMI
- OTHERS
- TEMA
- CHAUVIN ARNOUX
- FLUKE
- AMPROBE
- DEFELSKO
- Koronakis
- GOULDS
- BOSCH
- AXIS
- EUROGARDIAN
- ProPHOS
- POTTER ROMER
- SHIJIAZHUANG
- SCA SPECIAL CHEMICAL
- LARSON
- BARTH
- EXCESS
- JUST
- EURAMCO SAFETY
- FirePASS
Project
- Offshore Projects
- HVAC System
- FM-200 System
- Wellhead Control Panel
- Gas metering system
- Onshore projects
- Mechanical and Electrical
- Firefighting and Fire protection
- Lightning Systems
- HVAC
- Security, Computer Network
- Helicopter Underwater Escape Training (HUET) Models
- Intelligent warehouse
- Powder coasting system
- Extinguisher powder loading system
- Maintenance, Repair of fire protection, HVAC, Lightning systems
Weblinks
| 1. 245 kV CIRCUIT BREAKER | |||
| 1 | Manufacturer/Country of Origin | Siemens Ltd., India | |
| 2 | Ordering number |
Type: 3AP1 FG (Three Pole) Type: 3AP1 FI (Individual Pole) |
|
| I | Substantial requirements | ||
| 1 | Applicable standard | IEC 62271-100 | |
| 2 | Type | Outdoor, three-pole operation | |
| Outdoor, three single-pole operation | |||
| 3 | Interrupter units per pole | 1 | |
| 4 | Insulating medium | SF6 | |
| 5 | Rated voltage | kV | 220 |
| 6 | Highest system voltage | kV | 245 |
| 7 | Rated frequency | Hz | 50 |
| 8 | Rated current (In) | A |
Type 1: ≥1250 A Type 2: ≥2000 A |
| 9 | Rated three phase symmetrical short-circuit breaking current | kA rms. | 40 |
| 10 | Rated three phase symmetrical short circuit making current | kA peak | 100 |
| 11 | Rated duration of short-circuits | s | 3 |
| 12 | Rated Operating Sequence | O-0.3s-CO-3min-CO | |
| 13 | Lightning impulse voltage (1.2/50ms) withstand to earth | kV peak | 1050 |
| 14 | One minute power frequency voltage withstand to earth 50 Hz | kV rms. | 460 |
| 15 | First-pole-to-clear factor | 1,3 | |
| 16 | Minimum creepage distance | mm/kV | 25 |
| 17 | Operating mechanism |
3AP1 FG-Three-pole and 3AP1 FI- single pole |
|
| 18 | Operating mechanism drive type | Spring | |
| 19 | Minimum clearance between phase | mm | 2385 (type tested) |
| 20 | Minimum clearance to earth | mm | 2100 (type tested) |
| 21 | Operating times: (*) | ||
| - Opening time | ms | 37+4 | |
| - Closing time | ms | < 80 | |
| - Break time | ms | < 60 | |
| - Arcing time | ms | 25 | |
| 22 | Maximum time on auto-reclose of : (from trip energisation to instant of reclose main contacts) | ms | 3-30s three phases |
| 23 | Resistance of main contact (new contact) | mW | < 50 |
| 24 | Rated out-of phase breaking current | kA | 10 |
| 25 | Rated line charging breaking current | A rms. | 125 |
| 26 | Rated cable charging breaking current | A rms. | 250 |
| 27 | Rated small inductive breaking current | A rms. | (0-20)A at no load |
| 28 | Rated transient recovery voltage for terminal faults (T100) | kV peak | 364 kVp |
| 29 | Auxiliary power supply | ||
| - Voltage for heating and spring charged motor | Vac | 220 | |
| - Control, closing & tripping voltage | Vdc | 220 | |
| 30 | Number of tripping coil | pcs | 2 |
| 31 | Mechanical operation duration (In - class M2) | time |
10000 (at no load) (closing-opening) |
| 32 | Times tripping of 20kA (40kA) short circuit current without repair |
18 at 40kA 30 at 10kA |
|
| 33 | Power of closing, tripping coil of CB for all three phases | VA | < 1200 |
| 34 |
Type test for Mechanical operation duration (The contractor must provide type tests to demonstrate the parameters offered.) |
yes | Yes (enclosed) |
| 35 | Gas leakage rate | ≤0.5 %/year | |
| 36 |
Wired Control cubicle including: +Anti-pumping device + Pole discrepancy device + Local/remote control switch + SF6 density meter with alarm/trip contact + Auxiliary contact: at least 12NO & 12NC + Auxiliary contacts for charged spring signal and motor control + Heating and lighting device |
Yes Pole discrepency device not applicable for 3 pole operated breaker of type :3AP1 FG |
|
| 37 |
Common local control cabinet : - For type of single-pole circuit breaker, the common local control cabinet (combined from local control cubicles of three single - pole circuit breaker) must be equipped. The common local control shall allow operating independently closing/opening on each phase and operating simultaneously closing/opening on three phases of circuit breaker. Common control cabinet with connecting cables for electrical coupling of control cabinet with operating mechanism cubicle on each phase |
Yes | |
| 38 | Cabinets of the CB |
sheet steel; surface treated for anti-oxidation and paint coated with Zinc spray & polyurethene with ingress protection class of IP 55. |
|
| 39 | Steel structure | ||
| Height steel structure | mm | Yes | |
| Operating floor | Yes/No | Yes | |
| Height operating floor | mm | Yes | |
| 40 | Insulator | Porcelain, brown | |
| II | Non-substantial requirements | ||
| 1 | First-pole-to-clear factor | 1,3 | |
| 2 | Rated capacitive breaking current | A rms. | 400 (single phase) |
| 3 | Number of spare auxiliary contact | ||
| Normally opened | pcs | 12 | |
| Normally closed | pcs | 12 | |
| 4 | Materials of terminals | ||
| HV | Aluminium Alloy | ||
| 5 | Steel structure | ||
| Type | yes | ||
| Materials | yes | ||
| Height of structure | mm | yes | |
| III | Requirements for information | ||
| 1 | Rated times quanlities of circuit breaker | ||
| Opening time (no-load) | ms | 41ms (max) | |
| Closing time (no-load) | ms | 80ms (max) | |
| Open-close time (no-load) | ms |
380ms (including 300ms dead time) |
|
| Reclosing time (no-load) | ms |
400ms (including 300ms dead time) |
|
| Close-open time (no-load) | ms | 90ms | |
| 2 | SF6 gas | ||
| SF6 mass for one three-pole circuit breaker | kg | 21kg (3 pole) | |
| Rated SF6 density | kg/m3 | Pressure - 6.0 Bar @ 20 deg C (Rated) | |
| First threshold of SF6 density | kg/m3 | Pressure - 5.2 Bar @ 20 deg C (Alarm) | |
| Second threshold of SF6 density | kg/m3 | Pressure – 5.0 Bar @ 20 deg C (Trip/Lockout) | |
| SF6 gas pressure density gauss | SF6 gas density monitoring device | ||
| 3 | Max. noise level at 3 meters distance due to operation of circuit breaker | dB | ≤ 140dB |
| 4 | Max. impact load due to circuit breaker operation | kg |
23kN (Closing) 28kN (Opening) |
| 5 | Rated mechanical terminal load kN | kN | 2kN |
| 6 | Total weight of complete circuit breaker | kg | 3500kg (approx.) |
| 7 | Terminals (Dimensions : Holes - No. , size and spacing) | Please refer outline drawing | |
| HV | |||
| 8 | Drawings of steel structure | Yes/No | Yes |
| STT | ĐẶC TÍNH KỸ THUẬT | ĐƠN VỊ | |
| No | Specifications | Unit | |
| 2. 123 kV CIRCUIT BREAKER | |||
| 1 | Manufacturer/Country of Origin | Siemens Ltd., India | |
| 2 | Ordering number | CB Type: 3AP1 FG | |
| I | Substantial requirements | ||
| 1 | Applicable standard | IEC 62271-100 | |
| 2 | Type | Outdoor, 3 phase | |
| 3 | Insulating medium | SF6 | |
| 4 | Rated voltage | kV | 145 |
| 5 | Highest system voltage | kV | 123 |
| 6 | Rated frequency | Hz | 50 |
| 7 | Rated current (In) | ||
| Type 1 | A | 2000 | |
| Type 2 | A | 1250 | |
| 8 | Rated three phase symmetrical short-circuit breaking current | kA rms. | 40 |
| 9 | Rated three phase symmetrical short circuit making current | kA peak | 100 |
| 10 | Rated duration of short-circuits | s | 3 |
| 11 | Rated Operating Sequence | O-0.3s-CO-3min-CO | |
| 12 | Lightning impulse voltage (1.2/50ms) withstand to earth | kV peak |
650 kV peak (up to 1000m masl) |
| 13 | One minute power frequency voltage withstand to earth 50 Hz | kV rms. |
275 kV rms. (up to 1000m masl) |
| 14 | Minimum creepage distance | mm/kV | 25 (3625mm) |
| 15 | Operating mechanism | Three-pole | |
| 16 | Operating mechanism drive type | Spring | |
| 17 | Minimum clearance between phase | mm | 1360 |
| 18 | Minimum clearance to earth | mm | 1250 |
| 19 | Operating times: (*) | ||
| - Break time | ms | < 80 | |
| - Arcing time | ms | < 25 | |
| - Opening time | ms | < 60 | |
| - Closing time | ms | < 70 | |
| Maximum time on auto-reclose of : (from trip energisation to instant of reclose main contacts) | ms | 3-30s three phases | |
| 20 | Resistance of main contact (new contact) | mW | < 35 |
| 21 | Rated out-of phase breaking current | kA | 10kA |
| 22 | Rated line charging breaking current | A rms. | 50A |
| 23 | Rated cable charging breaking current | A rms. | 160A |
| 24 | Rated small inductive breaking current | A rms. |
(0-20)A (no load small magnetizing breaking current) |
| 25 | Rated transient recovery voltage for terminal faults (T100) | kV peak | 249kVp |
| 26 | Auxiliary power supply | ||
| - Voltage for heating and spring charged motor | Vac | 220 | |
| - Control, closing & tripping voltage | Vdc | 220 | |
| 27 | Number of tripping coil | pcs | 2 |
| 28 | Mechanical operation duration (In - class M2) | time |
10,000 cycles (closing-opening) |
| 29 |
Type test for Mechanical operation duration (The contractor must provide type tests to demonstrate the parameters offered.) |
yes | Yes |
| 30 | Gas leakage rate | ≤0.5 %/year | |
| 31 |
Wired Control cubicle including: +Anti-pumping device + Pole discrepancy device + Local/remote control switch + SF6 density meter with alarm/trip contact + Auxiliary contact: at least 12NO & 12NC + Auxiliary contacts for charged spring signal and motor control + Heating and lighting device |
Yes Pole discrepency device not is applicable for 3 pole operated breaker of type :3AP1 FG |
|
| 32 | Cabinets of the CB |
sheet steel; surface treated for anti-oxidation and paint coated with Zinc spray & polyurethene with ingress protection class of IP 55. |
|
| 33 | Height operating floor | mm | yes |
| 34 | Isolator |
Porcelain, brown (Insulator) |
|
| II | Non-substantial requirements | ||
| 1 | First-pole-to-clear factor | 1,3 | |
| 2 | Rated capacitive breaking current | A rms. | 400 |
| 3 | Number of spare auxiliary contact | ||
| Normally opened | pcs | 12 | |
| Normally closed | pcs | 12 | |
| 4 | Materials of terminals | ||
| HV | material | Aluminium Alloy | |
| 5 | Steel structure | ||
| Type | Yes | ||
| Materials | Yes | ||
| Height steel structure | mm | Yes | |
| III | Requirements for information | ||
| 1 | Rated times quanlities of circuit breaker | ||
| Opening time (no-load) | ms | 32+4 | |
| Closing time (no-load) | ms | < 80 | |
| Open-close time (no-load) | ms | 360ms (including 300ms dead time) | |
| Reclosing time (no-load) | ms | 400ms (including 300ms dead time) | |
| Close-open time (no-load) | ms | 80ms | |
| 2 | SF6 gas | ||
| SF6 mass for one three-pole circuit breaker | kg | 8.1 kg (3 pole) | |
| Rated SF6 density | kg/m3 | Pressure - 6.0 Bar @ 20 deg C (Rated) | |
| First threshold of SF6 density | kg/m3 | Pressure - 5.2 Bar @ 20 deg C (Alarm) | |
| Second threshold of SF6 density | kg/m3 | Pressure – 5.0 Bar @ 20 deg C (Trip/Lockout) | |
| SF6 gas pressure density gauss | SF6 gas density monitoring device | ||
| 3 | Max. noise level at 3 meters distance due to operation of circuit breaker | dB | ≤ 140dB |
| 4 | Max. impact load due to circuit breaker operation | kg |
Opening = 20 kN Closing = 15 kN |
| 5 | Rated mechanical terminal load kN | kN | 2 kN. |
| 6 | Minimum clearance between poles | mm |
1360 mm (Air clearance); 1700 mm (Pole center to center) |
| 7 | Minimum clearance to earth | mm | 1250mm (Phase to earth clearance) |
| 8 | Total weight of complete circuit breaker | kg | 1500kg (approx.) |
| 9 | Terminals (Dimensions : Holes - No. , size and spacing) | Please refer GA drawing | |
| HV | |||
| 10 | Drawings of steel structure | Yes/No | Yes |
Dowmload Catalogues: http://www.bhvietnam.com/dowload.php?id_code=6b429f7840b2528d54ccfebe94509207